LFY-293 Rain Test Device for Gloves (without high-voltage electrical system)
Main purpose
Rain test for long-sleeved composite insulating gloves.
Technical indicators
The calibrated resistivity at 20℃ is: (100 ± 15) Ω·m.
2. Rainfall rate is 1mm/min to 2mm/min.
3. The two separate openings of the rain gauge are each 100 - 750 cm³ in volume, and the depth is not less than half of the diameter.
4. The water storage tank can provide pre-rinsing for 15 minutes.
5. The duration of the wet test for both AC and DC voltages is 60 seconds.
6. The test requires the application of voltages of 10kV, 20kV, and 30kV. The test duration is 3 minutes.
7. The voltage rise rate for the test shall be 1000V/s, with a constant pressure increase speed.
Applicable standards (different standards require different accessories)
GB/T 17622-2008, GB/T 16927.1
Contact Us
Address: No. 195, Shandong Road, Shibei District, Qingdao City, Shandong Province
E-mail: tzfzyq@163.com
Contact Number
Instrumentation and Equipment: 0532-85614755 0532-85635588 13475428416
Inspection and Testing: 0532-85623450 0532-85634678
Scientific Journals: 0532-85648088
Scientific Services: 0532-85641981