LFY-602T 45° Angle Railway Vehicle Hard Material Flame Retardancy Tester
Scope of Application
The 45-degree angle combustion test applicable to the rigid flame-retardant materials for railway vehicles.
Technical requirements
1. Sample size: 160mm × 400mm
2. The sample is placed at a 45-degree angle.
3. The vertical distance from the center of the fuel container base to the center of the sample is 50mm.
4. The inner diameter of the fuel container is 35mm, the depth is 14mm, the wall thickness is 1mm, and the material is brass.
5. Timing device: Accuracy of 1 second
Applicable Standards
UIC-564-2-1991 International Railway Intermodal Transport or Railway Passenger Rolling Stock Fire Prevention and Fire Fighting Regulations - Appendix 4
Contact Us
Address: No. 195, Shandong Road, Shibei District, Qingdao City, Shandong Province
E-mail: tzfzyq@163.com
Contact Number
Instrumentation and Equipment: 0532-85614755 0532-85635588 13475428416
Inspection and Testing: 0532-85623450 0532-85634678
Scientific Journals: 0532-85648088
Scientific Services: 0532-85641981
Video Channel