产品详情

Main purposes: 
The LFY-607B thermal protection performance tester is used to measure the thermal insulation performance of flame-retardant protective clothing fabrics, fire protection clothing fabrics, flame-retardant insulation materials, fire boots, fire helmets, fire respirators, fire gloves, etc. when they are exposed to radiant heat sources and convective heat sources. Specifically, it measures the thermal protection performance values (TPP), thermal protection performance assessment (TPE), and anti-radiation penetration performance. This instrument is applicable for testing single-layer or multi-layer flame-retardant materials. 
Technical Specifications: 
1. The irradiated area of the sample: 100 cm² ± 0.01 cm² 

2. Heat Source: 
(1) The radiation heat source uses a specially designed T-150 infrared tube (with a 5-socket lamp holder), and the integrated voltage regulation range is: 0 to 220V. 
(2) The radiation intensity from the convection heat source can be continuously adjusted at an angle of 45 degrees. The convection heat source uses a self-made large-diameter self-generated lamp and a high-voltage pulse igniter. 
(3) Adopt the RT18-63R rapid protection circuit; 
(4) The guard rail and sample holder are equipped with large-stroke rodless cylinders. The movement speed can be adjusted, and the response time is less than 2 seconds. 
(5) Automatic ignition with high-voltage pulse; 
(6) The air leakage protection device can automatically cut off the air path electromagnetic valve; 
3. Temperature measurement range of the calorimeter: 0°C to 85°C ± 0.1°C; The calorimeter uses a dedicated plug-in design, allowing for quick and convenient switching. 
4. (1) Heat flux of the radiation heat source: 10 - 50 kW/m
(2) Heat flux of convective heat source: 10 - 50 kW/m2 
(3) Total heat flux: Adjustable from 50 kW/m2 to 100 kW/m2 (in accordance with the standard requirement, it should be 83 kW/m2 ± 2 kW/m2). ,

(4) Thermal source accuracy: ±2% 
(5) Methane flow rate adjustment range: 0 - 10 L/min 
(6) Air flow adjustment range: 0.6 - 6 m³/h 
5. Test indicators: Thermal protection coefficient (TPP), Thermal protection performance assessment (TPE), Radiation resistance penetration, Computer display of time-temperature curve. 
6. Instrument Structure: 
(1) It adopts an integrated stainless steel cabinet, with a rounded arc-shaped test chamber door that has a large opening area and is equipped with cylinder support; it is internally equipped with a fireproof and high-temperature-resistant exhaust hood; the fume hood and the instrument are designed as an integrated unit, making the operation convenient. 
(2) The instrument is equipped with a computer, featuring a Chinese operation interface, a Chinese test program, and automatic data processing. The test results are automatically saved, can be queried, and the test results and test reports can be exported. It can automatically generate reaction curves and human tissue tolerance curves, with the time accuracy reaching 0.1 seconds. 
(3) The instrument is equipped with a dedicated cooling gas gun for sensor components. After each test, the gas gun is used to cool the sensor components, which results in rapid cooling and enhances the efficiency of conducting large-scale tests. 
(4) Motion range of the guardrail and sample holder: 450mm, response time ≤ 2 seconds. 
(5) Built-in fireproof and high-temperature resistant exhaust hood: 0.35A / 220AC; 
(6) Both the guard fence and the sample holder are driven by large-stroke rodless cylinders as the main driving components. They have a large transmission stroke, adjustable movement speed, and fast response, which improves the response speed of the instrument tests and reduces measurement errors. 
(7) The sensor is sampled using a 12-bit high-speed A/D converter, which offers high sampling accuracy and fast speed. 
(8) The components of the instrument that are close to the heat source are all cooled by water. This not only ensures the service life of the components but also avoids the influence of the heat source temperature on the experimental results, thereby improving the overall testing accuracy of the instrument. 
7. Sample holder size: 150 × 150 mm 
8. Instrument dimensions: 1450mm × 630mm × 1350mm 
9. Power Supply: AC 220V, 50Hz, 6kW 
10. User-provided:
One set of methane gas cylinder and gas supply. 
Applicable standards: 

GB 8965.1-2020 Protective Clothing - Part 1: Flame Retardant Clothing 
GB/T 38302-2019 Protective Clothing - Test Methods for Thermal Protection Performance 
XF 10-2014 Firefighter Firefighting Protective Clothing 
GB/T 33536-2017 Protective Clothing - Forest Fire Protection Clothing 
XF 634 - 2015 Firefighter Thermal Insulation Protective Clothing 
XF 7-2004 Firefighter Gloves 
XF 6-2004 Firefighter Fire Extinguishing Protective Boots 
XF 44-2015 Fire Helmet 
XF 411-2003 Chemical Oxygen - Fire Self-Supporting Respirator - Appendix A 
FZ/T 73074-2023 Flame Retardant Knitted Clothing 
GB/T 17591-2025 Flame Retardant Fabrics

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Contact Us

 

Address: No. 195, Shandong Road, Shibei District, Qingdao City, Shandong Province

E-mail: tzfzyq@163.com

Contact Number 
Instrumentation and Equipment: 0532-85614755  0532-85635588  13475428416
Inspection and Testing: 0532-85623450  0532-85634678
Scientific Journals: 0532-85648088
Scientific Services: 0532-85641981

公众号二维码

Video Channel

公众号二维码

WeChat